Curious about Actual Dell EMC PowerEdge Operate (D-PE-OE-23) Exam Questions?
Here are sample Dell EMC Dell PowerEdge Operate 2023 (D-PE-OE-23) Exam questions from real exam. You can get more Dell EMC PowerEdge Operate (D-PE-OE-23) Exam premium practice questions at TestInsights.
A customer acquired six R750 servers. They must add these servers to their existing R760 iDRAC Group but are encountering errors.
What is the reason for the errors?
Correct : C
Understanding iDRAC Group Management and Compatibility
Server Management and Configuration Tools (14%)
Define the function of the iDRAC, login procedures, licensing, and connection methods
Explain the management interface options - LCC, racadm, OMSA, iSM, OME
System Administration (18%)
Configure BIOS, Storage, virtual media, networking, user access, lockdown mode, and group management
Scenario Analysis
The customer has acquired six Dell PowerEdge R750 servers and wants to add them to an existing iDRAC Group that currently contains R760 servers. However, they are encountering errors during this process.
Understanding Dell Server Generations
PowerEdge R750: Part of the 15th Generation (15G) servers.
PowerEdge R760: Part of the 16th Generation (16G) servers.
iDRAC Group Manager Limitations
iDRAC Group Manager allows administrators to manage multiple servers from a single interface.
Important Limitation: Servers of different generations cannot be grouped together in iDRAC Group Manager.
This is due to differences in firmware, hardware capabilities, and iDRAC features between server generations.
Impact: Attempting to add 15G servers (R750) to a group containing 16G servers (R760) will result in errors.
Evaluation of Options
Option A: R750 iDRACs firmware is out of date
Analysis: While outdated firmware can cause issues, it is not the primary reason here. Firmware updates would not resolve the incompatibility between different server generations.
Option B: R750 iDRACs are not running the same version of firmware
Analysis: Similar to Option A, firmware version mismatches can cause problems but not errors related to grouping different generations.
Option C: 15G and 16G servers cannot be in the same group
Correct Answe r: This is the primary reason for the errors encountered.
Option D: The feature requires iDRAC Enterprise
Analysis: Since the customer already has an existing iDRAC group with R760 servers, they likely have the necessary licensing.
Dell Operate Reference
Server Management and Configuration Tools (14%)
Emphasizes understanding iDRAC functionalities and limitations.
System Administration (18%)
Highlights the importance of group management and its constraints.
Conclusion
The errors occur because iDRAC Group Manager does not support grouping servers from different generations. The customer cannot add 15G servers (R750) to a group that contains 16G servers (R760).
Start a Discussions
A system board has been replaced on a Dell PowerEdge 16G server. What data can Easy Restore recover?
Correct : A
Understanding Easy Restore Functionality
Server Troubleshooting (32%)
Explain Easy Restore, diagnostic utilities, and hardware diagnostic options
What is Easy Restore?
Easy Restore is a feature in Dell PowerEdge servers that automatically restores system-specific information after a system board replacement.
Purpose: Minimizes downtime and simplifies recovery by retaining critical system identity information.
Data Restored by Easy Restore
Service Tag: The unique identifier (serial number) of the server.
System Configuration Settings: Includes BIOS settings and other non-volatile configurations.
Data NOT Restored by Easy Restore
Option B: HBA Configuration
Host Bus Adapter settings are not restored automatically.
Option C: PERC Configuration
RAID configurations need to be backed up and restored separately.
Option D: Lifecycle Controller Log
Logs are stored on the system board and do not transfer after replacement.
Evaluation of Options
Option A: Service Tag
Correct Answe r: Easy Restore recovers the Service Tag, preserving the server's identity.
Option B: HBA Configuration
Analysis: Requires manual configuration or restoration from a backup.
Option C: PERC Configuration
Analysis: RAID settings are critical but need separate backup and restoration procedures.
Option D: Lifecycle Controller Log
Analysis: Logs are not preserved after system board replacement.
Dell Operate Reference
Server Troubleshooting (32%)
Highlights the importance of understanding what Easy Restore can and cannot recover.
Conclusion
After replacing the system board on a Dell PowerEdge 16G server, Easy Restore will recover the Service Tag, ensuring the server maintains its unique identity within the network and management systems.
Start a Discussions
An administrator is in a non-secure location with a high latency connection. What option should be used to recover a PowerEdge server using an existing server profile?
Correct : D
Selecting the Appropriate Recovery Tool
Server Management and Configuration Tools (14%)
Explain the management interface options - LCC, racadm, OMSA, iSM, OME
Scenario Analysis
Constraints:
Non-secure location: Security of the connection is a concern.
High latency connection: Requires a tool that operates efficiently over slow networks.
Objective: Recover a PowerEdge server using an existing server profile.
Option Evaluations
Option A: iDRAC
Analysis: While iDRAC provides remote management, accessing it via a web interface may be slow and less secure in high latency and non-secure environments.
Option B: Redfish
Analysis: Redfish uses HTTPS, which is secure but may not perform well over high latency connections and requires more overhead.
Option C: IPMI
Analysis: IPMI lacks robust security features and is not recommended in non-secure locations.
Option D: RACADM
Correct Answer
Advantages:
Secure: Can use SSH for secure command-line access.
Efficient: Command-line interface minimizes bandwidth usage, suitable for high latency.
Powerful: Allows full management of the server, including applying existing server profiles.
Scriptable: Enables automation and faster recovery processes.
Understanding RACADM
RACADM (Remote Access Controller Admin):
A command-line utility for managing Dell servers via iDRAC.
Supports both local and remote management.
Ideal for automated scripts and low-bandwidth situations.
Dell Operate Reference
Server Management and Configuration Tools (14%)
Emphasizes understanding different management tools and their appropriate use cases.
System Administration (18%)
Covers configuring and managing servers in various environments.
Conclusion
Given the need for a secure and efficient tool in a high latency and non-secure location, RACADM is the optimal choice for recovering the PowerEdge server using an existing server profile.
Start a Discussions
The system administrator wants to ensure that the ability to change passwords is disabled in the BIOS. Which method can be used to achieve this?
Correct : A
Disabling Password Changes in BIOS
System Administration (18%)
Configure BIOS, Storage, virtual media, networking, user access, lockdown mode, and group management
Understanding the Requirement
The system administrator wants to prevent any changes to passwords within the BIOS. This means disabling the ability for any user to modify BIOS passwords, ensuring that the system's security settings remain intact.
Methods to Disable BIOS Password Changes
Set a System Board Jumper
Dell PowerEdge servers have a physical jumper on the system board (motherboard) known as the Password Disable Jumper. When this jumper is set, it disables the ability to change or clear BIOS passwords.
Purpose: This hardware-level setting overrides any software configurations, providing a secure method to prevent unauthorized password changes.
Implementation Steps:
Power down the server and disconnect it from the power source.
Locate the Password Disable Jumper on the system board. Refer to the server's hardware manual for the exact location.
Move the jumper to the 'Enabled' position as per the manufacturer's instructions.
Reconnect power and boot the server.
Other Options Analysis
Option B: Press the System ID Button
The System ID button is used to identify the server in a data center by illuminating an LED or displaying identification information. It does not affect BIOS password settings.
Conclusion: Not a method to disable password changes.
Option C: Ensure that no other users can log in to the iDRAC
Restricting iDRAC access prevents remote management but does not disable password changes in the BIOS through local access.
Conclusion: Does not fulfill the requirement.
Option D: Disable the password setting in the System Setup Utility
The System Setup Utility allows enabling or disabling password requirements but may not provide an option to disable password changes altogether.
Conclusion: May not effectively prevent password changes, as the setting could potentially be re-enabled.
Dell Operate Reference
Server Components (26%)
Understanding hardware features such as system board jumpers is crucial for managing server security.
System Administration (18%)
Emphasizes configuring user access and security settings, including BIOS configurations.
Conclusion
Setting the system board jumper is a reliable and hardware-enforced method to disable the ability to change BIOS passwords, ensuring that the security settings remain unaltered.
Start a Discussions
A system administrator plans to use iDRAC Direct to use features such as RACADM and WSMan. What is used to make the connection?
Correct : B
Understanding iDRAC Direct and Connection Methods
Server Management and Configuration Tools (14%)
Define the function of the iDRAC, login procedures, licensing, and connection methods
iDRAC Direct Overview
iDRAC Direct provides a direct connection to the Integrated Dell Remote Access Controller (iDRAC) using a USB interface.
Purpose: Allows administrators to perform management tasks locally without needing network access.
Features Accessed via iDRAC Direct:
RACADM: Remote Access Controller Admin CLI tool for managing iDRAC settings.
WS-Man: Web Services Management protocol for remote management.
Connection Interface
Physical Connection: Requires a USB cable connected between the administrator's laptop and the server's iDRAC Direct port.
Type of USB Port Used: Dell PowerEdge servers typically use a Micro USB port for iDRAC Direct connections.
Explanation of Options
Option A: USB-C
USB-C is a newer USB standard with a reversible connector. As of the knowledge cutoff in 2023, Dell servers primarily use Micro USB for iDRAC Direct, not USB-C.
Conclusion: Incorrect.
Option B: Micro USB
Correct Answe r: The iDRAC Direct port uses a Micro USB interface.
Option C: Mini USB
Mini USB is an older standard, larger than Micro USB, and not commonly used in modern servers for management interfaces.
Conclusion: Incorrect.
Option D: USB-A
USB-A refers to the standard rectangular USB port found on most computers. The server's iDRAC Direct port does not use USB-A.
Conclusion: Incorrect.
Dell Operate Reference
Server Management and Configuration Tools (14%)
Highlights the importance of understanding connection methods to iDRAC.
Define the function of the iDRAC, login procedures, licensing, and connection methods: Emphasizes knowledge of physical interfaces used for management.
Conclusion
To use iDRAC Direct features like RACADM and WS-Man, the system administrator needs to connect via the Micro USB port on the server.
Start a Discussions
Total 50 questions