Question 1

A customer acquired six R750 servers. They must add these servers to their existing R760 iDRAC Group but are encountering errors.

What is the reason for the errors?


Correct : C

Understanding iDRAC Group Management and Compatibility

Server Management and Configuration Tools (14%)

Define the function of the iDRAC, login procedures, licensing, and connection methods

Explain the management interface options - LCC, racadm, OMSA, iSM, OME

System Administration (18%)

Configure BIOS, Storage, virtual media, networking, user access, lockdown mode, and group management

Scenario Analysis

The customer has acquired six Dell PowerEdge R750 servers and wants to add them to an existing iDRAC Group that currently contains R760 servers. However, they are encountering errors during this process.

Understanding Dell Server Generations

PowerEdge R750: Part of the 15th Generation (15G) servers.

PowerEdge R760: Part of the 16th Generation (16G) servers.

iDRAC Group Manager Limitations

iDRAC Group Manager allows administrators to manage multiple servers from a single interface.

Important Limitation: Servers of different generations cannot be grouped together in iDRAC Group Manager.

This is due to differences in firmware, hardware capabilities, and iDRAC features between server generations.

Impact: Attempting to add 15G servers (R750) to a group containing 16G servers (R760) will result in errors.

Evaluation of Options

Option A: R750 iDRACs firmware is out of date

Analysis: While outdated firmware can cause issues, it is not the primary reason here. Firmware updates would not resolve the incompatibility between different server generations.

Option B: R750 iDRACs are not running the same version of firmware

Analysis: Similar to Option A, firmware version mismatches can cause problems but not errors related to grouping different generations.

Option C: 15G and 16G servers cannot be in the same group

Correct Answe r: This is the primary reason for the errors encountered.

Option D: The feature requires iDRAC Enterprise

Analysis: Since the customer already has an existing iDRAC group with R760 servers, they likely have the necessary licensing.

Dell Operate Reference

Server Management and Configuration Tools (14%)

Emphasizes understanding iDRAC functionalities and limitations.

System Administration (18%)

Highlights the importance of group management and its constraints.

Conclusion

The errors occur because iDRAC Group Manager does not support grouping servers from different generations. The customer cannot add 15G servers (R750) to a group that contains 16G servers (R760).


Options Selected by Other Users:
Mark Question:

Start a Discussions

Submit Your Answer:
0 / 1500
Question 2

A system board has been replaced on a Dell PowerEdge 16G server. What data can Easy Restore recover?


Correct : A

Understanding Easy Restore Functionality

Server Troubleshooting (32%)

Explain Easy Restore, diagnostic utilities, and hardware diagnostic options

What is Easy Restore?

Easy Restore is a feature in Dell PowerEdge servers that automatically restores system-specific information after a system board replacement.

Purpose: Minimizes downtime and simplifies recovery by retaining critical system identity information.

Data Restored by Easy Restore

Service Tag: The unique identifier (serial number) of the server.

System Configuration Settings: Includes BIOS settings and other non-volatile configurations.

Data NOT Restored by Easy Restore

Option B: HBA Configuration

Host Bus Adapter settings are not restored automatically.

Option C: PERC Configuration

RAID configurations need to be backed up and restored separately.

Option D: Lifecycle Controller Log

Logs are stored on the system board and do not transfer after replacement.

Evaluation of Options

Option A: Service Tag

Correct Answe r: Easy Restore recovers the Service Tag, preserving the server's identity.

Option B: HBA Configuration

Analysis: Requires manual configuration or restoration from a backup.

Option C: PERC Configuration

Analysis: RAID settings are critical but need separate backup and restoration procedures.

Option D: Lifecycle Controller Log

Analysis: Logs are not preserved after system board replacement.

Dell Operate Reference

Server Troubleshooting (32%)

Highlights the importance of understanding what Easy Restore can and cannot recover.

Conclusion

After replacing the system board on a Dell PowerEdge 16G server, Easy Restore will recover the Service Tag, ensuring the server maintains its unique identity within the network and management systems.


Options Selected by Other Users:
Mark Question:

Start a Discussions

Submit Your Answer:
0 / 1500
Question 3

An administrator is in a non-secure location with a high latency connection. What option should be used to recover a PowerEdge server using an existing server profile?


Correct : D

Selecting the Appropriate Recovery Tool

Server Management and Configuration Tools (14%)

Explain the management interface options - LCC, racadm, OMSA, iSM, OME

Scenario Analysis

Constraints:

Non-secure location: Security of the connection is a concern.

High latency connection: Requires a tool that operates efficiently over slow networks.

Objective: Recover a PowerEdge server using an existing server profile.

Option Evaluations

Option A: iDRAC

Analysis: While iDRAC provides remote management, accessing it via a web interface may be slow and less secure in high latency and non-secure environments.

Option B: Redfish

Analysis: Redfish uses HTTPS, which is secure but may not perform well over high latency connections and requires more overhead.

Option C: IPMI

Analysis: IPMI lacks robust security features and is not recommended in non-secure locations.

Option D: RACADM

Correct Answer

Advantages:

Secure: Can use SSH for secure command-line access.

Efficient: Command-line interface minimizes bandwidth usage, suitable for high latency.

Powerful: Allows full management of the server, including applying existing server profiles.

Scriptable: Enables automation and faster recovery processes.

Understanding RACADM

RACADM (Remote Access Controller Admin):

A command-line utility for managing Dell servers via iDRAC.

Supports both local and remote management.

Ideal for automated scripts and low-bandwidth situations.

Dell Operate Reference

Server Management and Configuration Tools (14%)

Emphasizes understanding different management tools and their appropriate use cases.

System Administration (18%)

Covers configuring and managing servers in various environments.

Conclusion

Given the need for a secure and efficient tool in a high latency and non-secure location, RACADM is the optimal choice for recovering the PowerEdge server using an existing server profile.


Options Selected by Other Users:
Mark Question:

Start a Discussions

Submit Your Answer:
0 / 1500
Question 4

The system administrator wants to ensure that the ability to change passwords is disabled in the BIOS. Which method can be used to achieve this?


Correct : A

Disabling Password Changes in BIOS

System Administration (18%)

Configure BIOS, Storage, virtual media, networking, user access, lockdown mode, and group management

Understanding the Requirement

The system administrator wants to prevent any changes to passwords within the BIOS. This means disabling the ability for any user to modify BIOS passwords, ensuring that the system's security settings remain intact.

Methods to Disable BIOS Password Changes

Set a System Board Jumper

Dell PowerEdge servers have a physical jumper on the system board (motherboard) known as the Password Disable Jumper. When this jumper is set, it disables the ability to change or clear BIOS passwords.

Purpose: This hardware-level setting overrides any software configurations, providing a secure method to prevent unauthorized password changes.

Implementation Steps:

Power down the server and disconnect it from the power source.

Locate the Password Disable Jumper on the system board. Refer to the server's hardware manual for the exact location.

Move the jumper to the 'Enabled' position as per the manufacturer's instructions.

Reconnect power and boot the server.

Other Options Analysis

Option B: Press the System ID Button

The System ID button is used to identify the server in a data center by illuminating an LED or displaying identification information. It does not affect BIOS password settings.

Conclusion: Not a method to disable password changes.

Option C: Ensure that no other users can log in to the iDRAC

Restricting iDRAC access prevents remote management but does not disable password changes in the BIOS through local access.

Conclusion: Does not fulfill the requirement.

Option D: Disable the password setting in the System Setup Utility

The System Setup Utility allows enabling or disabling password requirements but may not provide an option to disable password changes altogether.

Conclusion: May not effectively prevent password changes, as the setting could potentially be re-enabled.

Dell Operate Reference

Server Components (26%)

Understanding hardware features such as system board jumpers is crucial for managing server security.

System Administration (18%)

Emphasizes configuring user access and security settings, including BIOS configurations.

Conclusion

Setting the system board jumper is a reliable and hardware-enforced method to disable the ability to change BIOS passwords, ensuring that the security settings remain unaltered.


Options Selected by Other Users:
Mark Question:

Start a Discussions

Submit Your Answer:
0 / 1500
Question 5

A system administrator plans to use iDRAC Direct to use features such as RACADM and WSMan. What is used to make the connection?


Correct : B

Understanding iDRAC Direct and Connection Methods

Server Management and Configuration Tools (14%)

Define the function of the iDRAC, login procedures, licensing, and connection methods

iDRAC Direct Overview

iDRAC Direct provides a direct connection to the Integrated Dell Remote Access Controller (iDRAC) using a USB interface.

Purpose: Allows administrators to perform management tasks locally without needing network access.

Features Accessed via iDRAC Direct:

RACADM: Remote Access Controller Admin CLI tool for managing iDRAC settings.

WS-Man: Web Services Management protocol for remote management.

Connection Interface

Physical Connection: Requires a USB cable connected between the administrator's laptop and the server's iDRAC Direct port.

Type of USB Port Used: Dell PowerEdge servers typically use a Micro USB port for iDRAC Direct connections.

Explanation of Options

Option A: USB-C

USB-C is a newer USB standard with a reversible connector. As of the knowledge cutoff in 2023, Dell servers primarily use Micro USB for iDRAC Direct, not USB-C.

Conclusion: Incorrect.

Option B: Micro USB

Correct Answe r: The iDRAC Direct port uses a Micro USB interface.

Option C: Mini USB

Mini USB is an older standard, larger than Micro USB, and not commonly used in modern servers for management interfaces.

Conclusion: Incorrect.

Option D: USB-A

USB-A refers to the standard rectangular USB port found on most computers. The server's iDRAC Direct port does not use USB-A.

Conclusion: Incorrect.

Dell Operate Reference

Server Management and Configuration Tools (14%)

Highlights the importance of understanding connection methods to iDRAC.

Define the function of the iDRAC, login procedures, licensing, and connection methods: Emphasizes knowledge of physical interfaces used for management.

Conclusion

To use iDRAC Direct features like RACADM and WS-Man, the system administrator needs to connect via the Micro USB port on the server.