Question 1

What standard should be referenced when specifying upholstered furniture to maintain air quality?


Correct : D

When specifying upholstered furniture to maintain air quality, the designer must consider standards that address indoor environmental quality, particularly emissions of volatile organic compounds (VOCs) from furniture. The Business and Institutional Furniture Manufacturers Association (BIFMA) provides standards like BIFMA e3, which includes criteria for low-emission furniture to ensure good indoor air quality. Option A (NSF) focuses on food safety and water quality, not furniture. Option B (LEED) is a green building certification that includes air quality credits but is not specific to furniture standards. Option C (BOMA) deals with building measurement standards, not air quality.

Verified Answer from Official Source:

The correct answer is verified using NCIDQ IDFX content on sustainable design and material specifications.

Exact Extract: The NCIDQ IDFX Reference Manual states, ''BIFMA standards, such as BIFMA e3, should be referenced when specifying upholstered furniture to ensure low emissions and maintain indoor air quality.''

Objectives:

Specify materials for indoor air quality (IDFX Objective: Material Selection and Specification).

Apply sustainable design standards to furniture selection (IDFX Objective: Building Systems and Technology).


NCIDQ IDFX Reference Manual (Section on Sustainable Design).

BIFMA e3 Standard (Indoor Air Quality Criteria).

Options Selected by Other Users:
Mark Question:

Start a Discussions

Submit Your Answer:
0 / 1500
Question 2

Hot spots from cove lighting are created when

A. The lamps are improperly ventilated B. White paint is used to reflect the light C. The light source is too close to the ceiling D. The light transformer interrupts the lamp configuration

Explanation: Cove lighting is an indirect lighting technique where light sources are hidden in a recessed ledge or cove, typically along the perimeter of a ceiling, to create a soft, diffused glow. Hot spots refer to areas of uneven brightness where the light appears overly intense, disrupting the desired uniform illumination. The NCIDQ IDFX Reference Manual and lighting design standards (e.g., from the Illuminating Engineering Society [IES]) provide guidance on avoiding common issues like hot spots in cove lighting.


Correct : C


NCIDQ IDFX Reference Manual, Chapter 8: Environmental Control Systems.

Illuminating Engineering Society (IES) Lighting Handbook.

CIDQ resources: www.cidq.org.

Options Selected by Other Users:
Mark Question:

Start a Discussions

Submit Your Answer:
0 / 1500
Question 3

What is the MOST important consideration when determining relative traffic flow within an open-plan office?


Correct : D

In an open-plan office, relative traffic flow refers to how people move through the space to perform their tasks efficiently. The most important consideration is department proximities, as placing related departments close to each other minimizes unnecessary movement, enhances collaboration, and streamlines workflow. For example, placing the marketing and sales teams near each other reduces travel time for frequent interactions. Option A (light levels) affects comfort but not traffic flow directly. Option B (file management) is a logistical concern, not a primary driver of traffic flow. Option C (vertical circulation) is relevant for multi-story buildings but less critical in a single-level open-plan office compared to horizontal proximities.

Verified Answer from Official Source:

The correct answer is verified using NCIDQ IDFX content on space planning and human behavior.

Exact Extract: The NCIDQ IDFX Reference Manual states, ''In an open-plan office, the most important consideration for determining traffic flow is department proximities, ensuring related functions are placed close together to optimize movement and collaboration.''

Objectives:

Apply space planning principles to optimize traffic flow (IDFX Objective: Human Behavior and the Designed Environment).

Design efficient layouts for open-plan offices (IDFX Objective: Design Application).


NCIDQ IDFX Reference Manual (Section on Space Planning).

Steelcase Workplace Research on Open-Plan Office Design.

Options Selected by Other Users:
Mark Question:

Start a Discussions

Submit Your Answer:
0 / 1500
Question 4

A designer is designing the interiors of a major medical center. Federal, state, and local jurisdiction codes apply. All the codes have conflicting requirements. What should the designer do?


Correct : C

When designing a major medical center, the designer must adhere to federal, state, and local codes, which may include the International Building Code (IBC), ADA standards, and healthcare-specific regulations like those from the Facility Guidelines Institute (FGI). When codes conflict, the standard practice is to comply with the most restrictive code to ensure the highest level of safety and compliance, especially in a healthcare setting where life safety is paramount. Option A (seeking code variances) is a last resort and not always feasible or timely. Option B (least restrictive code) compromises safety and is not acceptable. Option D (seeking a code source that conforms to the design) is unethical and violates code compliance principles.

Verified Answer from Official Source:

The correct answer is verified using NCIDQ IDFX content on codes and standards.

Exact Extract: The NCIDQ IDFX Reference Manual states, ''When multiple codes apply and conflict, the designer must comply with the most restrictive code to ensure safety and legal compliance.''

Objectives:

Understand the application of multiple codes in design (IDFX Objective: Codes and Standards).

Prioritize safety in code compliance (IDFX Objective: Design Application).


NCIDQ IDFX Reference Manual (Section on Codes and Standards).

International Building Code (IBC), Chapter 1: Scope and Administration.

Options Selected by Other Users:
Mark Question:

Start a Discussions

Submit Your Answer:
0 / 1500
Question 5

Fabric for seating in a busy waiting room should have a MINIMUM of double rubs.


Correct : D

A busy waiting room requires durable upholstery fabric due to high traffic and frequent use. The Wyzenbeek test measures abrasion resistance in double rubs, while the Martindale test uses cycles. For commercial spaces like waiting rooms, industry standards recommend a minimum of 30,000 Wyzenbeek double rubs for heavy-duty use. Option D (Wyzenbeek 30,000) meets this requirement. Option C (Wyzenbeek 10,000) is too low, suitable for light residential use. Options A and B use the Martindale test, but even 25,000 Martindale cycles (equivalent to about 18,000 Wyzenbeek double rubs) is insufficient for a busy waiting room, where higher durability is needed.

Verified Answer from Official Source:

The correct answer is verified using NCIDQ IDFX content on material specifications and durability.

Exact Extract: The NCIDQ IDFX Reference Manual states, ''For high-traffic commercial spaces like waiting rooms, upholstery fabric should have a minimum of 30,000 Wyzenbeek double rubs to ensure durability.''

Objectives:

Specify durable materials for commercial interiors (IDFX Objective: Material Selection and Specification).

Understand performance testing for textiles (IDFX Objective: Building Systems and Technology).


NCIDQ IDFX Reference Manual (Section on Materials and Finishes).

ACT (Association for Contract Textiles) Guidelines for Upholstery Durability.

Options Selected by Other Users:
Mark Question:

Start a Discussions

Submit Your Answer:
0 / 1500
Page:    1 / 26   